SVS Series

Servo Electronic
Voltage Stabilisers & Power Line Conditioners
Single Phase
1 to 100 kVA

SVS Series - Single-Phase
Servo Electronic AC Voltage Stabilizers -
1 to 100kVA

Suitable for 95% of all applications, SVS Servo Electronic Stabilisers  not only guard against voltage fluctuations they also offer protection against all too common harmful high-energy surges, transients and voltage spikes.

Remastered to meet the demands of today’s modern age, our latest generation SVS Series models deliver a step-less automated regulation of the incoming utility mains supply.

Offered as two ranges, in ratings from 1 to 100 kVA, H Series models support international 220 to 240 Volt mains supplies and L Series models support US-Style utility supplies of 100 to 127 volts.

To learn more about the range of  Single-Phase SVS Voltage Stabilisers and Power Conditioners available from Sinalda UK, please check out the following listings, or download the brochure below:

SINALDA

Standard Features include:

Automatic Step-Less Voltage Stabilisation / Regulation 
Cost-Efficient Servo Electronic Design 
Wide Permissible Input Voltage Window (up to ±40%) 
Precise Output Voltage Accuracy (Adjustable ±1% to ±5%) 
Extremely Low Maintenance 
TVSS – Transient Voltage Surge & Spike Suppression Protection 
Inbuilt High Overload Capability 
Over / Low Voltage Protection 
Start Up Load Protection 
Class II SPD – Lightning Surge Arrestor 

Digital Monitoring & Display Panel

  • Output Voltage Metering
  • Output Current Metering
  • Operational Status Indication
 
Automatic Restart on Mains Failure
Re-start Time Delay (Presettable)
Input Circuit Breaker  
Electronic Controls Bypass Switch 
Hard Wire Input & Output (with Bottom / Rear Cable Entry) 
Freestanding IP20 Indoor Enclosure 
Built to comply with leading International Standards 
Supplied with a 3 Year / 36 Months Warranty 


Optional Features
available include:

Outdoor IP54 Enclosure (-IP54)
Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments
Input Isolating Transformer (-PC)
Through the integration of a shielded isolation transformer, provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply
Full Manual Maintenance Bypass (-MBS)
While many Customers, following traditional wisdom, prefer to install a bypass facility that is external to the Stabilizer/Conditioner, where requested models can be fitted with an integrated traditional ‘Break Before Make’ bypass facility. This feature is handy when performing remedial works or deep maintenance on the system.
Digital Power Metering (-DPM)
Microprocessor-based output digital power metering, with event logging – monitoring V, A, W, VAR, PF, W Hrs & VAR Hrs and the offering  RS-485, Modbus RTU, Modbus ASCII, Jbus Protocol interface
Alternative Paint Colour (-RAL)
Alternative Paint Colour Finish – customer to specify
Output Circuit Breaker (-OCB)
An Output Circuit Breaker to protect the load  against overload and short circuit
UL Recognised Component (-URC)
For 
applications where UL compliance is required, the Stabilizer / Conditioner can be supplied with UL approved Input Breakers and Output Contactors / Breakers, so that the client can obtain on-site UL approval of the installation

SELECT | Permissible Input Voltage Window Options (S*):

Swing OptionsNominal VoltageMax Model Rating
220V230V240V
S15±15%187 to 253V196 to 265V204 to 276V100 kVA
S20±20%176 to 264V184 to 276V192 to 288V75 kVA
S25±25%165 to 275V173 to 288V180 to 300V60 kVA
S30±30%154 to 286V161 to 299V168 to 312V50 kVA
S35±35%143 to 297V150 to 311V156 to 329V40 kVA
S40±40%132 to 308V136 to 322V144 to 336V30 kVA

SELECT | Required Power Rating:

Power Rating (kVA)Max Rating (Amps per Phase)SVS-H-S* Model No
(S*
=Select Swing Option Required)
220V230V240V
1 kVA4.5A4.3A4.2ASVS-1H-S30~S40
2 kVA9.1A8.7A8.3ASVS-2H-S30~S40
3 kVA13.6A13.0A12.5ASVS-3H-S30~S40
4 kVA18A17A17ASVS-4H-S30~S40
5 kVA23A22A21ASVS-5H-S30~S40
8 kVA36A35A33ASVS-8H-S30~S40
10 kVA46A44A42ASVS-10H-S20~S40
15 kVA68A65A63ASVS-15H-S15~S40
20 kVA91A87A83ASVS-20H-S15~S40
25 kVA113a108A104ASVS-25H-S15~S40
30 kVA136A130A125ASVS-30H-S15~S40
40 kVA182A174A167ASVS-40H-S15~S35
50 kVA227A217A208ASVS-50H-S15~S30
60 kVA273A261A250ASVS-60H-S15~S25
75 kVA341A326A313ASVS-75H-S15~S20
80 kVA363A347A333ASVS-80H-S15
100 kVA455A435A417ASVS-100H-S15

Note: All SVS-Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.

Also available as a Voltage Step-Down Solution (HL Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 230V / Load Requirement 120V)

SELECT | Permissible Input Voltage Window Options (S*):

Swing OptionsNominal VoltageMax Model Rating
100V110V
115V120V127V
S15±15%85 to 115V94 to 127V98 to 132V102 to 138V106 to 146V60 kVA
S20±20%80 to 120V88 to 132V92 to 138V96 to 144V102 to 152V50 kVA
S25±25%75 to 125V83 to 138V86 to 144V90 to 150V95 to 159V40 kVA
S30±30%70 to 130V77 to 143V81 to 150V84 to 156V89 to 165V30 kVA

SELECT | Required Power Rating:

Power Rating (kVA)Max Rating (Amps per Phase)SVS-L-S* Model No
(S*
=Select Swing Option Required)
100V110V115V
120V127V
1 kVA10A9A8.7A
8.3A7.9ASVS-1L-S20~S30
2 kVA20A18A17.4A
16.7A15.7ASVS-2L-S20~S30
3 kVA30A27A26A
25A23ASVS-3L-S20~S30
4 kVA40A36A34A
33A31ASVS-4L-S15~S30
5 kVA50A46A44A
42A39ASVS-5L-S15~S30
8 kVA80A73A70A
67A63ASVS-8L-S15~S30
10 kVA100A91A87A
83A78ASVS-10L-S15~S30
15 kVA150A136A130A
125A118ASVS-15L–S15~S30
20 kVA200A182A174A
167A157ASVS-20LP-S15~S30
30 kVA300A273A261A
250A236ASVS-30L-S15~S30
40 kVA400A364A348A
333A315ASVS-40L-S15~S25
50 kVA500A454A434A416A393ASVS-50L-S15~S20
60 kVA600A545A521A500A472ASVS-60L-S15

Note:
All SVS Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature

Also available as a Voltage Step-Up Solution (LH Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 120V / Load Requirement 230V)

General Technical Specification

General:
 – Design Topology:Servo Electronic – Variable Transformer controlled
 – Phase:Single Phase, 2 Wire (L+N+GE)
 – Model Nos:H SeriesSVS-1H-S* to SVS-100H-S* ( 1 to 100 kVA)
 L SeriesSVS-1L-S* to SVS-60L-S* (1 to 60 kVA)
 – Power Ratings:17 Model Ratings-
1kVA, 2 kVA, 3kVA, 4kVA, 5 kVA, 8 kVA, 10kVA, 15kVA, 20kVA, 25kVA, 30kVA, 40kVA, 50kVA, 60kVA, 75kVA, 80 kVA  & 100kVA
 – Frequency:50 / 60Hz (47 to 63Hz)
 – Power Factor:The Power Factor has no effect on performance providing the stabilizer is being used within its rated capacity
Input:
 – Nominal Voltage:H Series 220V – 230V – 240V, Single Phase, 2 Wire (L+N+GE)
L Series110V – 120V – 127V, Single Phase, 2 Wire (L+N+GE)
 – Input Voltage Window Options (S*):S15Nominal ±15% (All Series)
 S20Nominal ±20% (All Series)
 S25Nominal ±25% (All Series)
 S30Nominal ±30% (All Series)
 S35Nominal ±35% (H Series Only)
 S40Nominal ±40% (H Series Only)
Output:
 – Voltage:H Series 220V – 230V – 240V (Customer to Specify), Single Phase, 2 Wire (L+N+GE)
 L Series100V – 110V – 120V – 127V (Customer to Specify), Single Phase, 2 Wire (L+N+GE)
 – Voltage Accuracy:S15 to S30 Option Models±1% (Default) – adjustable ±1% to ±5%
 S35 to S40 Option Models±1% (Default) – adjustable ±3% to ±5%
 – Response Time:Typically a 10% supply variation will be corrected to within 2.5% in 0.6 seconds
 – Overload Ratings:150% max. current rating for 10 seconds
 – Efficiency:≥98%
Metering, Alerts & Communication:
 – Front Display Panel:Digital Metering:Output Volts, and Load
 Status Indication:On, Output Over and Under Volts & Output Normal & SPD Fault
Protection Features:
 – Surge Protection:TVSS – Protects loads against high-energy Spikes and Transient Voltages
 – Lightning Surge Protection:Class II SPD – protection against extremely high voltage surges and transients caused by lightning strikes on the utility mains supply line
 – Input Breaker:Standard on all models – delivers over current input protection
 – Bypass:Inbuilt Bypass Switch enabling the bypassing of the electronic controls circuitry to provide power direct to the load
Environmental:
 – Operating Temperature Range:-15°C to +45°C
Derate by 2% for each additional °C up to max 60°C
 – Maximum Altitude:1000 meters (derate by 2.5% per additional 500 meters)
 – Relative Humidity:Suitable for indoor tropical use – 0 to 95% (non-condensing)
Physical:
 – Power Connections:Hardwire Input & Output (with bottom cable entry)
 – Construction:IP20 / NEMA 1 Style – BS EN 60529
 – Paint Colour:RAL 7032 (Pebble Grey – Epoxy Powder Coating) – Other paint colours on specific request
 – Dimensions & Weights:Dependent on model rating and configuration
Sizes and weights available on individual request
Certification & Conformance:
 – EMC Conformance:BS EN 55022 and relevant parts of BS EN 61000
 – CE Certification:CE Marked – 2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive)
 – Warranty:3 Years / 36 Months from date of supply
Optional Add-Ons: 
– Outdoor IP54 Enclosure (-IP54)Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments
– Input Isolating Transformer (-PC)Through the integration of a shielded isolation transformer, provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply
– Full Manual Maintenance Bypass (-MBS)An integrated/inbuilt traditional ‘Break Before Make’ bypass facility. Handy when performing remedial works, or deep maintenance on the system.
– AquaStop (-AS)PCB protective coating offering protection against damp and moisture ingress
– Digital Metering (-DPM)Output Digital Power Metering for monitoring V, A, W, VAR, PF, W Hrs & VAR Hrs and offering  RS-485 interface and event logging
– Output Circuit Breaker (-OCB)Replacement of the Output Contactor with an Output Circuit Breaker
– Alternative Paint Colour (-RAL)Alternative Paint Colour Finish – customer to specify
– UL Recognised Components (-URC)For applications where UL compliance is required, the Stabilizer / Conditioner can be supplied with UL approved Input Breakers and Output Contactors / Breakers, so that the client can obtain on-site UL approval of the installation

Note:
All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.

Sales & Support

Data Sheet

– H Series   [220V, 230V, or 240V Models]

– L Series   [100V, 110V, 115V, 120V or 127V Models]

Guide Specification

Operator / User Manual

Please contact us to request a copy of the Manual

CE Certification

SVS Series Single Phase Servo Electronic AC Voltage Stabilisers / Conditioners comply with the relevant European Union (EU) health, safety and environmental protection directives and regulations and are duly CE marked.

Sinalda Declaration

EMC Directive – 2014/30/EU – in force from April 2016

Low Voltage Directive – 2014/35/EU – in force from April 2016

 

If you do not find the Voltage Stabiliser or Power Line Conditioner that meets your application’s exact needs, please contact us with your specific detailed requirements.