[vc_row][vc_column][vc_column_text]Single Phase Variable Transformers in ratings from 3 to over 80 Amps. Available with either Manual (AE Series) or Motorized (MAE Series) control.
Unlike fixed ratio transformers, Ashley-Edison’s Variac style auto-transformers provide an infinitely variable step-less output voltage that can be adjusted from 0 to 117% of the nominal input voltage.
The available 240V (HB/HO) and 120V (LB/LO) manual and motoristed controlled single phase variable transformer ranges are detailed in the TABs below.
AE-HB Series - 3 to 80 Amps Nominal Voltage Manually operated 220V to 240V single phase variable transformers from 3 to 80 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of the line voltage. Supplied as standard to IP20 (NEMA 1 Style) enclosures, with terminal covers, the casings can be easily removed for 'Open' style and panel mount applications. To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free Amps AE Model Nominal kVA @ max Output Dimensions Weight Volts AC Output Volts Volts AC W x H x D (mm) (Kgs) 3 Amps AE-203-HB 220V 0.77 0 to 257V 164 x 150 x 210 6 240V 0.84 0 to 280V 5 Amps AE-205-HB 220V 1.2 0 to 257V 164 x 150 x 210 7 230V 1.3 0 to 268V 240V 1.4 0 to 280V 10 Amps AE-210-HB 220V 2.5 0 to 257V 215 x 160 x 260 11 230V 2.6 0 to 268V 240V 2.8 0 to 280V 15 Amps AE-215-HB 220V 3.8 0 to 257V 215 x 160 x 260 13 230V 4.0 0 to 268V 240V 4.0 0 to 280V 20 Amps AE-220-HB 220V 5.1 0 to 257V 230V 5.3 0 to 268V 240V 5.6 0 to 280V 25 Amps AE-225-HB 30 Amps AE-230-HB 35 Amps AE-235-HB 40 Amps AE-240-HB 50 Amps AE-2252-HB 60 Amps AE-2302-HB 80 Amps AE-2402-HB Note: Other voltage configurations and larger ratings available upon enquiry / order. Input Voltage: +6% of nominal (ie. 240V models are continuoulsy rated at 254V) Output Voltage: Continuously variable from 0 to 117% of input voltage Frequency: 47 to 65 Hz Power Factor: Any Efficiency: 98% Surge Rating: 10 x max current rating for 1 second 3 x max current rating for 60 seconds 2 x max current rating for 5 minutes Environment: Temperature Range -15°to 45° C Derate by 2% for each additional °C up to max 60°C Suitable for indoor tropical use 95% RH (non-condensing) Maximum altitude 1000m. Derate by 2.5% for each additional 500m. Standards Compliance: BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 CE Conformity: CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) RoHS Compliance: RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standard Warranty: One (1) Year / Twelve (12) Months from date of supply. NOTES: Safety Caution: When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. Typical Applications: Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers AE-LB Series - 3 to 80 Amps Nominal Voltage Manually operated 110V to 120V single phase variable transformers from 3 to 80 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of the line voltage. Supplied as standard to IP20 (NEMA 1 Style) enclosures, with terminal covers, the casings can be easily removed for 'Open' style and panel mount applications. To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free Amps AE Model Nominal kVA @ max Output Dimensions Weight Volts AC Output Volts Volts AC W x H x D (mm) (Kgs) 3 Amps AE-103-LB 110V 0.38 0 to 129V 164 x 150 x 210 4.5 120V 0.42 0 to 140V 5 Amps AE-105-LB 110V 0.64 0 to 129V 164 x 150 x 210 5 115V 0.67 0 to 134V 120V 0.70 0 to 140V 10 Amps AE-110-LB 110V 1.2 0 to 129V 164 x 150 x 210 6.5 115V 1.3 0 to 134V 120V 1.4 0 to 140V 15 Amps AE-115-LB 110V 1.9 0 to 129V 215 x 160 x 260 10 115V 2.0 0 to 134V 120V 2.1 0 to 140V 20 Amps AE-120-LB 110V 2.5 0 to 129V 115V 2.6 0 to 134V 120V 2.8 0 to 140V 25 Amps AE-125-LB 30 Amps AE-130-LB 35 Amps AE-135-LB 40 Amps AE-140-LB 50 Amps AE-150-LB 60 Amps AE-1302-LB 80 Amps AE-1402-LB Note: Other voltage configurations and larger ratings available upon enquiry / order. Input Voltage: +6% of nominal (ie. 120V models are continuoulsy rated at 127V) Output Voltage: Continuously variable from 0 to 117% of input voltage Frequency: 47 to 65 Hz Power Factor: Any Efficiency: 98% Surge Rating: 10 x max current rating for 1 second 3 x max current rating for 60 seconds 2 x max current rating for 5 minutes Environment: Temperature Range -15°to 45° C Derate by 2% for each additional °C up to max 60°C Suitable for indoor tropical use 95% RH (non-condensing) Maximum altitude 1000m. Derate by 2.5% for each additional 500m. Standards Compliance: BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 CE Conformity: CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) RoHS Compliance: RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standard Warranty: One (1) Year / Twelve (12) Months from date of supply. NOTES: Safety Caution: When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. Typical Applications: Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers MAE-HO Series - 3 to 80 Amps Nominal Voltage Motorised 220V to 240V single phase variable transformer assemblies, from 3 to over 80 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of line voltage. Presented as ‘Open’ style motorised variable transformer assemblies, with the compact motor drive mounted on top of the variable transformer, the systems are presented uncased. In such formats, MAE models are ideal for incorporation as component assemblies in OEM style systems. To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free Amps AE Model Nominal kVA @ max Output Dimensions Weight Volts AC Output Volts Volts AC W x H x D (mm) (Kgs) 3 Amps MAE-203-HO 220V 0.77 0 to 257V 164 x 290 x 210 9 240V 0.84 0 to 280V 5 Amps MAE-205-HO 220V 1.2 0 to 257V 164 x 290 x 210 10 230V 1.3 0 to 268V 240V 1.4 0 to 280V 10 Amps MAE-210-HO 220V 2.5 0 to 257V 215 x 300 x 260 14 230V 2.6 0 to 268V 240V 2.8 0 to 280V 15 Amps MAE-215-HO 220V 3.8 0 to 257V 215 x 300 x 260 16 230V 4.0 0 to 268V 240V 4.0 0 to 280V 20 Amps MAE-220-HO 220V 5.1 0 to 257V 230V 5.3 0 to 268V 240V 5.6 0 to 280V 25 Amps MAE-225-HO 30 Amps MAE-230-HO 35 Amps MAE-235-HO 40 Amps MAE-240-HO 50 Amps MAE-2252-HO 60 Amps MAE-2302-HO 80 Amps MAE-2402-HO Note: Other voltage configurations and larger ratings available upon enquiry / order. Input Voltage: +6% of nominal (ie. 240V models are continuoulsy rated at 254V) Output Voltage: Continuously variable from 0 to 117% of input voltage Frequency: 47 to 65 Hz Power Factor: Any Efficiency: 98% Surge Rating: 10 x max current rating for 1 second 3 x max current rating for 60 seconds 2 x max current rating for 5 minutes Environment: Temperature Range -15°to 45° C Derate by 2% for each additional °C up to max 60°C Suitable for indoor tropical use 95% RH (non-condensing) Maximum altitude 1000m. Derate by 2.5% for each additional 500m. Options: MAE-HB fully cased IP20 (NEMA 1 Style) solutions with - Digital Metering (DM) - Input Circuit Breaker (CB) - Push Button Voltage Selection Standards Compliance: BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 CE Conformity: CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) RoHS Compliance: RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standard Warranty: One (1) Year / Twelve (12) Months from date of supply. NOTES: Safety Caution: When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. Typical Applications: Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers MAE-LO Series - 3 to 80 Amps Nominal Voltage Motorised 110V to 120V single phase variable transformer assemblies, from 3 to over 80 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of line voltage. Presented as ‘Open’ style motorised variable transformer assemblies, with the compact motor drive mounted on top of the variable transformer, the systems are presented uncased. In such formats, MAE models are ideal for incorporation as component assemblies in OEM style systems. To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free Amps AE Model Nominal kVA @ max Output Dimensions Weight Volts AC Output Volts Volts AC W x H x D (mm) (Kgs) 3 Amps MAE-103-LO 110V 0.38 0 to 129V 164 x 290 x 210 9 120V 0.42 0 to 140V 5 Amps MAE-105-LO 110V 0.64 0 to 129V 164 x 290 x 210 10 115V 0.67 0 to 134V 120V 0.70 0 to 140V 10 Amps MAE-110-LO 110V 1.2 0 to 129V 164 x 290 x 210 11 115V 1.3 0 to 134V 120V 1.4 0 to 140V 15 Amps MAE-115-LO 110V 1.9 0 to 129V 215 x 300 x 260 14 115V 2.0 0 to 134V 120V 2.1 0 to 140V 20 Amps MAE-120-LO 110V 2.5 0 to 129V 115V 2.6 0 to 134V 120V 2.8 0 to 140V 25 Amps MAE-125-LO 30 Amps MAE-130-LO 35 Amps MAE-135-LO 40 Amps MAE-140-LO 50 Amps MAE-150-LO 60 Amps MAE-1302-LO 80 Amps MAE-1402-LO Note: Other voltage configurations and larger ratings available upon enquiry / order. Input Voltage: +6% of nominal (ie. 120V models are continuoulsy rated at 127V) Output Voltage: Continuously variable from 0 to 117% of input voltage Frequency: 47 to 65 Hz Power Factor: Any Efficiency: 98% Surge Rating: 10 x max current rating for 1 second 3 x max current rating for 60 seconds 2 x max current rating for 5 minutes Environment: Temperature Range -15°to 45° C Derate by 2% for each additional °C up to max 60°C Suitable for indoor tropical use 95% RH (non-condensing) Maximum altitude 1000m. Derate by 2.5% for each additional 500m. Options: MAE-LB fully cased IP20 (NEMA 1 Style) solutions with - Digital Metering (DM) - Input Circuit Breaker (CB) - Push Button Voltage Selection Standards Compliance: BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 CE Conformity: CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) RoHS Compliance: RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Standard Warranty: One (1) Year / Twelve (12) Months from date of supply. NOTES: Safety Caution: When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. Typical Applications: Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers
Single Phase Manually Operated Variable Transformers
220 to 240V Single Phase, 50/60Hz Downloads
eDataSheet PDF DataSheet Pricing to either e-mail us or call us on +44 (0)870 240 6162 230V 0.80 0 to 268V 300 x 225 x 345 19 220V 6.4 0 to 257V 300 x 225 x 345 23 230V 6.7 0 to 268V 240V 7.0 0 to 280V 220V 7.7 0 to 257V 300 x 225 x 345 24 230V 8.0 0 to 268V 240V 8.4 0 to 280V 220V 9.0 0 to 257V 300 x 225 x 345 26 230V 9.3 0 to 268V 240V 9.8 0 to 280V 220V 10.2 0 to 257V 370 x 260 x 425 35 230V 10.7 0 to 268V 240V 11.0 0 to 280V 220V 12.8 0 to 257V 300 x 375 x 400 47 230V 13.4 0 to 268V 240V 14.0 0 to 280V 220V 15.4 0 to 257V 300 x 375 x 400 50 230V 16.0 0 to 268V 240V 16.8 0 to 280V 220V 20.5 0 to 257V 370 x 400 x 490 71 230V 21.4 0 to 268V 240V 22.4 0 to 280V
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
Single Phase Manually Operated Variable Transformers
110 to 120V Single Phase, 50/60Hz Downloads
eDataSheet PDF DataSheet Pricing to either e-mail us or call us on +44 (0)870 240 6162 115V 0.40 0 to 134V 215 x 160 x 260 11.5 110V 3.2 0 to 129V 215 x 160 x 260 13 115V 3.3 0 to 134V 120V 3.5 0 to 140V 110V 3.8 0 to 129V 300 x 225 x 345 21 115V 4.0 0 to 134V 120V 4.2 0 to 140V 110V 4.5 0 to 129V 300 x 225 x 345 23 115V 4.6 0 to 134V 120V 4.9 0 to 140V 110V 5.1 0 to 129V 300 x 265 x 345 25 115V 5.3 0 to 134V 120V 5.6 0 to 140V 110V 6.4 0 to 129V 370 x 260 x 425 35 115V 6.7 0 to 134V 120V 7.0 0 to 140V 110V 7.7 0 to 129V 300 x 375 x 400 43 115V 8.0 0 to 134V 120V 8.4 0 to 140V 110V 10.3 0 to 129V 370 x 455 x 400 51 115V 10.7 0 to 134V 120V 11.2 0 to 140V
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
Single Phase Motorised Variable Transformers
220 to 240V Single Phase, 50/60Hz Downloads
eDataSheet PDF DataSheet Pricing to either e-mail us or call us on +44 (0)870 240 6162 230V 0.80 0 to 268V 300 x 390 x 345 24 220V 6.4 0 to 257V 300 x 390 x 345 27 230V 6.7 0 to 268V 240V 7.0 0 to 280V 220V 7.7 0 to 257V 300 x 390 x 345 28 230V 8.0 0 to 268V 240V 8.4 0 to 280V 220V 9.0 0 to 257V 300 x 390 x 345 30 230V 9.3 0 to 268V 240V 9.8 0 to 280V 220V 10.2 0 to 257V 370 x 420 x 425 39 230V 10.7 0 to 268V 240V 11.0 0 to 280V 220V 12.8 0 to 257V 300 x 530 x 425 50 230V 13.4 0 to 268V 240V 14.0 0 to 280V 220V 15.4 0 to 257V 300 x 530 x 400 54 230V 16.0 0 to 268V 240V 16.8 0 to 280V 220V 20.5 0 to 257V 370 x 580 x 490 75 230V 21.4 0 to 268V 240V 22.4 0 to 280V
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
Single Phase Motorised Variable Transformers
110 to 120V Single Phase, 50/60Hz Downloads
eDataSheet PDF DataSheet Pricing to either e-mail us or call us on +44 (0)870 240 6162 115V 0.40 0 to 134V 215 x 300 x 260 16 110V 3.2 0 to 129V 215 x 300 x 260 18 115V 3.3 0 to 134V 120V 3.5 0 to 140V 110V 3.8 0 to 129V 300 x 390 x 345 26 115V 4.0 0 to 134V 120V 4.2 0 to 140V 110V 4.5 0 to 129V 300 x 390 x 345 28 115V 4.6 0 to 134V 120V 4.9 0 to 140V 110V 5.1 0 to 129V 300 x 390 x 345 30 115V 5.3 0 to 134V 120V 5.6 0 to 140V 110V 6.4 0 to 129V 370 x 420 x 425 40 115V 6.7 0 to 134V 120V 7.0 0 to 140V 110V 7.7 0 to 129V 300 x 530 x 400 48 115V 8.0 0 to 134V 120V 8.4 0 to 140V 110V 10.3 0 to 129V 370 x 580 x 400 56 115V 10.7 0 to 134V 120V 11.2 0 to 140V
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE