[vc_row][vc_column][vc_column_text]Manually operated Three Phase Variable Transformers in ratings from 10 to over 80 Amps.
With digital metering and input circuit breaker protection, Ashley-Edison’s AE-DM-CB Series Variable Transformers are ideal for three phase electrical / electronic testing laboratory environments.
The available 400V (HB), 208V (LB) and 480V (HB-480) three phase variable transformer ranges are detailed in the TABs below.
Manually operated 380V to 415V three phase variable transformers from 10 to 80 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of the line voltage.
Supplied as standard in IP20 (NEMA 1 Style) enclosures on castors, with digital metering and input circuit breaker protection. |
|
Amps per Phase | AE Model | Nominal | kVA @ max | Output | Dimensions | Weight |
| Volts AC | Output Volts | Volts AC | W x H x D (mm) | (Kgs) | |
10 Amps | AE-3210-HB-DM-CB | 380V | 7.7 | 0 to 445V | 500 x 600 x 600 | 115 |
400V | 8.1 | 0 to 468V | ||||
415V | 8.4 | 0 to 485V | ||||
15 Amps | AE-3215-HB-DM-CB | 380V | 11.6 | 0 to 445V | 500 x 600 x 600 | 125 |
400V | 12.2 | 0 to 468V | ||||
415V | 12.6 | 0 to 485V | ||||
20 Amps | AE-3220-HB-DM-CB | 380V | 15.4 | 0 to 445V | 500 x 680 x 600 | 130 |
400V | 16.2 | 0 to 468V | ||||
415V | 16.8 | 0 to 485V | ||||
25 Amps | AE-3225-HB-DM-CB | 380V | 19.3 | 0 to 445V | 500 x 680 x 600 | 140 |
400V | 20.3 | 0 to 468V | ||||
415V | 21.0 | 0 to 485V | ||||
30 Amps | AE-3230-HB-DM-CB | 380V | 23.1 | 0 to 445V | 500 x 680 x 600 | 145 |
400V | 24.3 | 0 to 468V | ||||
415V | 25.2 | 0 to 485V | ||||
35 Amps | AE-3235-HB-DM-CB | 380V | 27.0 | 0 to 445V | 600 x 680 x 700 | 165 |
400V | 28.4 | 0 to 468V | ||||
415V | 29.4 | 0 to 485V | ||||
40 Amps | AE-3240-HB-DM-CB | 380V | 30.8 | 0 to 445V | 600 x 680 x 700 | 185 |
400V | 32.4 | 0 to 468V | ||||
415V | 33.5 | 0 to 485V | ||||
50 Amps | AE-32252-HB-DM-CB | 380V | 38.6 | 0 to 445V | Dimensions and Weights | |
400V | 40.6 | 0 to 468V | ||||
415V | 42.0 | 0 to 485V | ||||
60 Amps | AE-32302-HB-DM-CB | 380V | 46.3 | 0 to 445V | Dimensions and Weights | |
400V | 48.6 | 0 to 468V | ||||
415V | 50.4 | 0 to 485V | ||||
70 Amps | AE-32352-HB-DM-CB | 380V | 54.0 | 0 to 445V | Dimensions and Weights | |
400V | 56.7 | 0 to 468V | ||||
415V | 58.8 | 0 to 485V | ||||
80 Amps | AE-32402-HB-DM-CB | 380V | 61.6 | 0 to 445V | Dimensions and Weights | |
400V | 64.8 | 0 to 468V | ||||
415V | 67.2 | 0 to 485V |
Note: Other voltage configurations, as well as smaller & larger ratings, available to special order.
Input Voltage: | +6% of nominal (ie. 415V models are continuoulsy rated at 439V) |
Output Voltage: | Continuously variable from 0 to 117% of input voltage |
Frequency: | 47 to 65 Hz |
Power Factor: | Any |
Efficiency: | 98% |
Surge Rating:
| 10 x max current rating for 1 second |
3 x max current rating for 60 seconds | |
2 x max current rating for 5 minutes | |
Environment: | Temperature Range -15°to 45° C |
| Derate by 2% for each additional °C up to max 60°C |
| Suitable for indoor tropical use 95% RH (non-condensing) |
| Maximum altitude 1000m. Derate by 2.5% for each additional 500m. |
Standard Features: | Input Circuit Breaker |
Output Terminal Block | |
Digital Voltmeter / Ammeter (Selector Switch) | |
Manual Operation - Knob Rotation | |
Free Standing IP20 (NEMA 1 Style) Enclosure on Castors | |
Optional Accessories: | Output Circuit Breaker |
Input Voltage Stabiliser | |
Motorised Operation - see MAE-HB-DM-CB Series | |
Industrial Output Socket | |
Standards Compliance: | BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 |
CE Conformity: | CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) |
RoHS Compliance: | RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment |
Standard Warranty: | One (1) Year / Twelve (12) Months from date of supply. |
NOTES:
Safety Caution: | When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. | |
Typical Applications: | Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers |
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
Manually operated 190V to 208V three phase variable transformers from 10 to 40 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of the line voltage.
Supplied as standard in IP20 (NEMA 1 Style) enclosures on castors, with digital metering and input circuit breaker protection. |
|
Amps per Phase | AE Model | Nominal | kVA @ max | Output | Dimensions | Weight |
| Volts AC | Output Volts | Volts AC | W x H x D (mm) | (Kgs) | |
10 Amps | AE-3110-HB-DM-CB | 190V | 3.8 | 0 to 222V | 400 x 520 x 400 | 45 |
200V | 4.0 | 0 to 234V | ||||
208V | 4.2 | 0 to 243V | ||||
15 Amps | AE-3115-HB-DM-CB | 190V | 5.7 | 0 to 222V | 500 x 520 x 500 | 65 |
200V | 6.0 | 0 to 234V | ||||
208V | 6.3 | 0 to 243V | ||||
20 Amps | AE-3120-HB-DM-CB | 190V | 7.6 | 0 to 222V | 500 x 600 x 500 | 70 |
200V | 8.1 | 0 to 234V | ||||
208V | 8.4 | 0 to 243V | ||||
25 Amps | AE-3125-HB-DM-CB | 190V | 9.6 | 0 to 222V | 500 x 600 x 500 | 78 |
200V | 10.1 | 0 to 234V | ||||
208V | 10.5 | 0 to 243V | ||||
30 Amps | AE-3230-HB-DM-CB | 190V | 11.5 | 0 to 222V | 500 x 650 x 600 | 100 |
200V | 12.1 | 0 to 234V | ||||
208V | 12.6 | 0 to 243V | ||||
35 Amps | AE-3135-HB-DM-CB | 190V | 13.4 | 0 to 222V | 500 x 700 x 600 | 120 |
200V | 14.1 | 0 to 234V | ||||
208V | 14.7 | 0 to 243V | ||||
40 Amps | AE-3140-HB-DM-CB | 190V | 15.3 | 0 to 222V | 500 x 700 x 600 | 130 |
200V | 16.2 | 0 to 234V | ||||
208V | 16.8 | 0 to 243V |
Note: Other voltage configurations, as well as smaller & larger ratings, available to special order.
Input Voltage: | +6% of nominal (ie. 208V models are continuoulsy rated at 220V) |
Output Voltage: | Continuously variable from 0 to 117% of input voltage |
Frequency: | 47 to 65 Hz |
Power Factor: | Any |
Efficiency: | 98% |
Surge Rating:
| 10 x max current rating for 1 second |
3 x max current rating for 60 seconds | |
2 x max current rating for 5 minutes | |
Environment: | Temperature Range -15°to 45° C |
| Derate by 2% for each additional °C up to max 60°C |
| Suitable for indoor tropical use 95% RH (non-condensing) |
| Maximum altitude 1000m. Derate by 2.5% for each additional 500m. |
Standard Features: | Input Circuit Breaker |
Output Terminal Block | |
Digital Voltmeter / Ammeter (Selector Switch) | |
Manual Operation - Knob Rotation | |
Free Standing IP20 (NEMA 1 Style) Enclosure on Castors | |
Optional Accessories: | Output Circuit Breaker |
Input Voltage Stabiliser | |
Motorised Operation - see MAE-LB-DM-CB Series | |
Industrial Output Socket | |
Standards Compliance: | BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 |
CE Conformity: | CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) |
RoHS Compliance: | RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment |
Standard Warranty: | One (1) Year / Twelve (12) Months from date of supply. |
NOTES:
Safety Caution: | When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. | |
Typical Applications: | Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers |
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
Manually operated 440V to 480V three phase variable transformers from 10 to 60 amps - delivering an efficient and trouble free method of varying AC voltages with an output from zero to 117% of the line voltage.
Supplied as standard in IP20 (NEMA 1 Style) enclosures on castors, with digital metering and input circuit breaker protection. |
|
Amps per Phase | AE Model | Nominal | kVA @ max | Output | Dimensions | Weight |
| Volts AC | Output Volts | Volts AC | W x H x D (mm) | (Kgs) | |
10 Amps | AE-3210-HB-DM-CB-480 | 440V | 8.9 | 0 to 515V | Dimensions and Weights | |
460V | 9.3 | 0 to 538V | ||||
480V | 9.7 | 0 to 562V | ||||
15 Amps | AE-3215-HB-DM-CB-480 | 440V | 13.4 | 0 to 515V | Dimensions and Weights | |
460V | 14.0 | 0 to 538V | ||||
480V | 14.6 | 0 to 562V | ||||
20 Amps | AE-3220-HB-DM-CB-480 | 440V | 17.8 | 0 to 515V | Dimensions and Weights | |
460V | 18.6 | 0 to 538V | ||||
480V | 19.5 | 0 to 562V | ||||
25 Amps | AE-3225-HB-DM-CB-480 | 440V | 22.3 | 0 to 515V | Dimensions and Weights | |
450V | 23.3 | 0 to 538V | ||||
480V | 24.3 | 0 to 562V | ||||
30 Amps | AE-3230-HB-DM-CB-480 | 440V | 26.8 | 0 to 515V | Dimensions and Weights | |
460V | 28.0 | 0 to 538V | ||||
480V | 29.2 | 0 to 562V | ||||
35 Amps | AE-3235-HB-DM-CB-480 | 440V | 31.2 | 0 to 515V | Dimensions and Weights | |
460V | 32.6 | 0 to 538V | ||||
480V | 34.1 | 0 to 562V | ||||
40 Amps | AE-3240-HB-DM-CB-480 | 440V | 35.7 | 0 to 515V | Dimensions and Weights | |
460V | 37.3 | 0 to 538V | ||||
480V | 38.9 | 0 to 562V | ||||
50 Amps | AE-32252-HB-DM-CB-480 | 440V | 44.6 | 0 to 515V | Dimensions and Weights | |
460V | 46.6 | 0 to 538V | ||||
480V | 48.7 | 0 to 562V | ||||
60 Amps | AE-32302-HB-DM-CB-480 | 440V | 53.5 | 0 to 515V | Dimensions and Weights | |
460V | 55.9 | 0 to 538V | ||||
480V | 58.4 | 0 to 562V |
Note: Other voltage configurations, as well as smaller & larger ratings, available to special order.
Input Voltage: | +6% of nominal (ie. 480V models are continuoulsy rated at 508V) |
Output Voltage: | Continuously variable from 0 to 117% of input voltage |
Frequency: | 47 to 65 Hz |
Power Factor: | Any |
Efficiency: | 98% |
Surge Rating:
| 10 x max current rating for 1 second |
3 x max current rating for 60 seconds | |
2 x max current rating for 5 minutes | |
Environment: | Temperature Range -15°to 45° C |
| Derate by 2% for each additional °C up to max 60°C |
| Suitable for indoor tropical use 95% RH (non-condensing) |
| Maximum altitude 1000m. Derate by 2.5% for each additional 500m. |
Standard Features: | Input Circuit Breaker |
Output Terminal Block | |
Digital Voltmeter / Ammeter (Selector Switch) | |
Manual Operation - Knob Rotation | |
Free Standing IP20 (NEMA 1 Style) Enclosure on Castors | |
Optional Accessories: | Output Circuit Breaker |
Input Voltage Stabiliser | |
Motorised Operation - see MAE-HB-DM-CB-480 Series | |
Industrial Output Socket | |
Standards Compliance: | BS EN 61558-1:2005 + AI:2009 & BS EN 61558-2-13:2009 |
CE Conformity: | CE Marked - being fully compliant with European Union Directive 2006/95/EC (The Low Voltage Directive in force from January 2007) |
RoHS Compliance: | RoHS - being fully compliant with European Union Directive 2011/65/EU – the EU directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment |
Standard Warranty: | One (1) Year / Twelve (12) Months from date of supply. |
NOTES:
Safety Caution: | When using variable transformers, installation and connection must be carried out in accordance with relevant safety standards and care must be taken to ensure local regulations are strictly adhered to. When utilised as components in other systems, the variable transformers must never be used without suitable safety protection being in place. | |
Typical Applications: | Quality Control Testing, Low Voltage Performance Evaluation, Electronic Equipment Burn-In, Furnace Transformers, Test Benches, Lighting Dimmers, High Voltage Test Sets & DC Rectifiers |
Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE
If you do not find the variable transformer that meets your application’s exact needs, please contact us with your specific detailed requirements.[/vc_column_text][/vc_column][/vc_row]